Frankenslot FS Speedflow Eco Wave V3.17 Wireless 2,4ghz for Carrera Digital
1 Each wireless controller for the digital system Carrera D132 / 124
now with a new trigger lever for single- or two-finger operation - easily replaced - without controller disassembly
the controller functions with a microcontroller, all the functions of our Speedflow controller box are integrated into this controller.
The connection to the Carrera system via the Carrera wireless receiver
Operating on two standard batteries of size AAA - it's a continuous operation for more than 80 hours of high-quality batteries possible
The controller has an ON / OFF switch and an LED display
Software version V1.05
Speedflow wireless controller v2. 1
Technical data
Run-time continuous Operation
|
about 84 hours with 2 x AAA Duracell industrial
|
Survival in the standby
|
approx. 9 months
|
Power consumption When OFF
|
Real power separation. No consumption
|
Power consumption in standby
|
about 200 uA
|
Power consumption in operational
|
approx. 16 mA
|
operating instructions
Setting the channel to use and connect with the receiver
Switch the controller off. Recipient select the Desired channel to the Carrera. During power-up hold the switch button on the controller. Receiver Acknowledges the programming with the "7-segment run". Controller ready to go.
The configuration mode
Control what connected with receiver. Switch the controller off. Regulator gas completely Call by pressing hold and hold switch button and then turn on controller. LED goes on. To let go of the switch button and trigger the configuration begins.
The configuration is done based on the Speedflow box programming
The selection of the Desired Configuration value is done by briefly pressing of the switch button. Storing the value selected is Carried Out by the LED hold acknowledged Storing the Lane Change-button, to a rapid flash. After that, the next configuration option is Indicated by flashing. The Following configuration options are available.
Number of speed levels
- 1 x Flash - original Carrera 16 speeds
- 3 x Flash - Speedflow regulation 30 speeds
- 4 x blinking - Speed Flow Regulation 44 speed steps
Selection: press Save: pressing, until LED flashes rapidly.
Launch control active or switched off
- 1 x deactivated
- 2 x flashing launch control is available
Selection: press Save: pressing, until LED flashes rapidly.
Select performance curve
Here, the translation of the trigger position in the performance level of the car can be set. Specifies the number of flashes Which curve is selected.
Selection: press Save: pressing, until LED flashes rapidly